The ETH8020 provides 20 volt free contact relay outputs with a current rating of up to 16Amp each and 8 analogue inputs. The module is powered from a 12vdc supply which can be regulated or unregulated. The DC input jack is 2.1mm with positive core polarity, DC supplies are required to supply at least 1A at 12vdc. The relays are SPCO (Single Pole Change Over) types. The normally open, normally closed and common pins are all available on the screw terminals.
The Relays on the ETH8020 can be controlled from the inputs on the ETH484. This offers the opportunity to construct a system where an input can control an output anywhere on the earth provided both locations are connected to the network/internet.
-Operating Temperature
-40C to +70C
LED Indication
The ETH8020 provides a red LED mounted immediately next to each relay to indicate whether it is in a powered state (LED on), there is also two LED's mounted in the Ethernet connector which will flash with Ethernet traffic. Finally there is a green power LED next to the processor.
Relay Power Rating
If the contact load voltage and current of the relay are in the region enclosed by the solid and dotted lines in the figure below, the relay can perform stable switching operation. If the relay is used at a voltage or current exceeding this region, the life of the contacts may be significantly shortened.
load type | Typical applications | Rating | Max DC load capacity
|
AC1 | Non inductive or slightly inductive loads |
16A @ 250V AC | |
AC15 | Control of electromagnetic load (>72VA) |
3A @ 120V AC 1.5A @ 240V AC |
|
AC3 | Control of motor | 750W | |
DC1 | Non inductive or slightly inductive loads |
16A @ 24V DC | |
DC13 | Control of electromagnetic loads |
0.22A @ 120V DC 0.1A @ 250V DC |
A full datasheet for the relays used on the ETH8020 is here: HF115FD datasheet
Connections
16A Volt Free Contacts, Normally Connected, Common, Normally Open |
Analogue inputs | |
12v dc 2.1mm jack (+ve core)
RJ45 Ethernet
|
![]() |
5v dc output P = Analogue Input (0-5v)
|
16A Volt Free Contacts, Normally Connected, Common, Normally Open |
First Test
Having plugged in your 12vdc power supply and Ethernet connection, start up your web browser and type http://ETH8020 into the address bar, please note this only works in windows. You will be prompted for a password as shown below:
|
The default login is: Username: admin Password: password The ability to change these settings is shown in the configuration section |
You should now see the following web page:
This web page will allow you to switch the relays on and off by clicking the relay buttons (the red/gray circles). It also contains a link to this technical documentation page.
Configuration
By clicking the configuration link it's possible to configure the ETH8020 IP address and subnet mask together with the ability to set a password for entry to control screens. Gateway address and DNS address is configurable and is used with mapped inputs which are described in section below. The also offers the option to set a password that will be required to change any of the relay states or digital outputs using TCP IP commands, this is explained in the TCP/IP password section.
All settings are saved to memory so be careful to remember the username and password! Default password settings are shown in the picture below.
Factory Reset
Should it be necessary to reset the ETH8020 to its shipped condition then the end two contacts of the row of 5 holes near the large chip on the side nearest the Ethernet connection must be shorted together at board power up. Keep the pins shorted until the green power LED starts to flash, this will take up to 5 seconds. The green LED will flash as the settings are reset, please wait until the LED finishes flashing and do not remove power during this period.
Firmware Updates
The firmware is fully updateable by re-flashing the board using our custom windows program. This will be made available in the event of feature updates.
ETH8020 Command Set
The command set designed to provide consistent expansion and new features, they are sent over TCP/IP on port 17494 (0x4456). This is the default port, it can be changed in the configuration settings.
Five connections are allowed at any one time, these are independently protected but all using the same password as defined in the board configuration.
Command |
Action |
|
dec | hex | |
16 | 10 | Get Module Info - returns 3 bytes. Module Id (21 for ETH8020), Hardware version, Firmware version. |
32 | 20 | Digital Active - follow with 1-20 to set relay on, then a time for pulsed output from 1-255 (100ms resolution) or 0 for permanent |
33 | 21 | Digital Inactive - follow with 1-20 to turn relay off, then a time for pulsed output from 1-255 (100ms resolution) or 0 for permanent |
35 | 23 | Digital Set Outputs - follow with 3 bytes, first byte will set relays 1-8, All on = 255 (0xFF), All off = 0, 2nd byte for relays 9-16, 3rd byte for relays 17-20 |
36 | 24 | Digital Get Outputs - returns 3 bytes, the first corresponds with relays 1-8, 2nd byte for relays 9-16, 3rd byte for relays 17-20 |
37 | 25 | Digital Get Inputs - returns 4 bytes, the first three bytes are always 0, the 4th bytes bits correspond with the 8 digital inputs, a high bit meaning input is active (driven low) |
49 | 31 | Get Analogue Voltage - follow with 1-8 for channel and ETH8020 will respond with 2 bytes to form an 16-bit integer (high byte first) |
119 | 77 | Get Serial Number - Returns the unique 6 byte MAC address of the module. |
120 | 78 | Get Volts - returns relay supply voltage as byte, 125 being 12.5V DC |
121 | 79 | Password Entry - see TCP/IP password |
122 | 7A | Get Unlock Time - see section below |
123 | 7B | Log Out - immediately re-enables TCP/IP password protection |
Digital Active/Inactive Commands
These are 3 byte commands:
The first byte is the command, 32 (active means on) or 33 (inactive).
Second byte is the relay number.
Third byte is the on time. Set this to zero for un-timed operation, or 1-255 for a pulse in 100mS intervals (100mS to 25.5 seconds).
For example:
0x20 - turn the relay on command
0x03 - relay 3
0x32 (50) - 5 seconds (50 * 100ms)
Note - All bytes in a command must be sent in one TCP/IP packet.
Digital inputs
The 8 analogue inputs are used to create 8 digital inputs. When you request digital inputs a threshold is applied to the 8 analogue inputs. Above 3v will read as low (inactive), below 2v will read as high (active). The region from 2v to 3v is the hysteresis and does not change the previous reading. There are weak pull-up resistors on the inputs which are designed to allow you to directly connect a VFC (Volt Free Contact). This could be from other relay contacts, thermostat contacts, alarm contacts etc. When the contacts are closed the input will read as active. In fact anything that pulls the input pin down to 0v will read as active. Do not think of the inputs in terms of a high or low voltage input. Think of it in terms of Active (or on, something is actively driving the input), or inactive (or off, nothing is driving the input). Command of 0x25 returns 4 bytes. The first 3 bytes are always 0. The two bytes returned will be encoded with each bit corresponding to whether the input is active or inactive. A high bit means the pin is being pulled low (active) by an external device pulling low.
Analogue Inputs
Eight (8) analogue inputs of 0v-5V at 10-bit resolution are provided. The conversion is performed when you send the "Get Analogue Voltage" command 0x31 and the channel number. The resulting 16 bit integer will be transmitted back in two bytes (high byte first), combine these for the result. The 10-bit conversion will be in the lower 10 bits of the 16 bit integer with the upper 6 bits being 0. There is a 5v supply available on the 3-pin terminal block between the analogue inputs .
Representative Analogue Input Schematic.
TCP/IP Password
If this option is enabled in the http configuration page then a password will be required to be entered before relay states can be changed. In the following example the password was set to "apple":
0x79 - 1st byte in frame sent to ETH8020 to indicate password entry
'a' (0x61) - 2nd byte in frame (ASCII hex equivalent in brackets, full table is available at http://www.asciitable.com/)
'p' (0x70) - 3rd byte in frame
'p' (0x70) - 4th byte in frame
'l' (0x6C) - 5th byte in frame
'e' (0x65) - 6th byte in frame
These 6 bytes are then transmitted in the same transaction to the ETH8020 and if the password is correct then 1 will transmitted back, a failure will send 2.
The board will now accept changes from the device that entered the password. If communication becomes idle for more than 30 seconds then the password protection is re-enabled. There is also a log-out command of 0x7B to enable the protection immediately.
Get Unlock Time
Returns TCP/IP password protection status:
0 - password protection is enabled and password entry is required before changes can be made
1 to 30 - seconds until TCP/IP password protection is re-enabled. All authorised commands set the timer back to 30 seconds (including this one).
255 - TCP/IP password is not enabled.
IP Addresses & DHCP Servers
The easiest way to use the ETH8020 is to connect it to a network with a DHCP server. In this case the ETH8020 will have its IP address assigned automatically by the DHCP server.
If there is no DHCP server on the network, then a fixed IP address of 192.168.0.200 is used. To control the ETH8020 using this fixed IP address your computer MUST be on the same subnet.
The next step is to set your computers IP address to 192.168.0.x where x is in the range of 1 to 255 but not 200 (the ETH8020 is there!) or any other used IP addresses on the network.
The subnet mask dictates what IP addresses the PC can communicate with, we set this to 255.255.255.0 so the PC can talk to any module with an IP address of 192.168.0.x
The default gateway is likely to be the IP address that the internet connection is located at and the DNS server can be either your router address or google provide a DNS service at 8.8.8.8..
|
Test program and example source code
To get the ETH8020 up and running in the minimum amount of time we have put together an example program to demonstrate the functionality of the module. We provide the full source code for this program. You may examine this code to see how it works or use it as a starting point for your own application.
Visual studio express C# examples
The test program is available as Visual C# express ready built installation files here, or as Visual C# express project with source files here.
Visual studio express is provided free from Microsoft: http://www.microsoft.com/exPress/download/
Access from the Internet
The ETH8020 can be controlled over the internet almost as easily as on your local network. Your network will most likely be connected to the internet with a broadband router. This will provide NAT (Network Address Translation) and Firewall services. To access the ETH8020 from the internet you will need to open up port 17494 (or whichever port you have your module set to - you can select any port you wish) to allow incoming TCP connections. Be careful not to open up any other ports. There are a wide variety of routers and we cannot give details for all of them. If in doubt ask your system administrator for assistance. The following shows how to open up a port on a Netgear DG834 router.
After logging on to your routers setup page, the first thing to do is create a new service. Click on the "Services" menu then "Add Custom Service". Enter a name for the service, select TCP and enter the ETH8020's port address for both the start and finish ports. Click "Apply".
Now go to the "Firewall Rules" menu and click "Add" in the Inbound services section. Select the ETH8020 service and ALLOW always. The "Send to LAN Server" IP address is the ETH8020's IP address, 192.168.0.97 in the example above but check what it is on your network. Click "Apply" and that's it. The ETH8020 is now accessible over the internet. Before you close the routers setup pages, go to the "Router Status" menu and make a note of its ADSL port IP address. This is the routers internet facing IP address.
To test this you will need a computer that has its own internet connection and is NOT connected to the same network as the ETH8020. Download and run the test program above and select Custom IP. In the pop-up box enter your routers internet facing IP address. Click on "Try IP" and it will connect you to the ETH8020 just as if it were on your own network.
Android & iPhone Apps.
We have a free app IO network available for Android and iPhone to remotely control your relays, download from Google Play or iTunes. Search for "Devantech" and you will find the app.
Board dimensions
Specifiche
Part. No. : | ETH8020 |
Interfaccia : | Ethernet |
Rele' : | 20 |
Questions on ETH8020 - 20 Relays at 16A, 8 Analogue Inputs
-
19/12/16 13.53 buongiorno, è possibile il controllo della presente scheda tramite pagina web modificata (esempio: script api PHP) o comunque implementare una pagina web creata allo scopo con i comandi per pilotarla senza dover ricorrere al basic?
In attesa di un Vostro riscontro,
cordiali saluti
Francesco
Prodotti correlati
-
807486 ETH008 - 8 relay outputs at 16A
Questo modulo fornisce 8 relè con contatti da 16A, pilotabili tramite rete LAN. Il modulo viene alimentato a 12V (anche non sfalse -
807487 ETH484 - 4 Relays at 16A, 8 Digital IO and 4 Analogue Inputs
Questo modulo fornisce 4 relè con contatti da 16A, 8 inputs digitali e 4 inputs analogici; pilotabili tramite rete LAN. Il mofalse -
807988 ETH002 - 16Amp, 2 Channel Relay Module
Questo modulo fornisce 2 relè con contatti da 16A, pilotabili tramite rete LAN. Il modulo viene alimentato a 12V (anche non sfalse -
808246 ETH0621 - 24v Motor controller 5A - Ethernet
The ETH0621 offers 6 digital inputs (accepting 10V - 24V), 2 independently switched 24V 5A outputs and a 24 volt, 5A motor cfalse -
808408 WIFI008 - 8 Relays at 16A
The WIFI002 provides 2 volt free contact relay outputs with a current rating of up to 16Amp each, the module is powered from false -
808839 ETH8020C - Case for the ETH8020
ETH8020 case. Includes mounting holes for fixing to a wall or back panel. This precision snap together case includes screws ffalse -
849494 ETH008-B - 8 relay outputs at 16A
Questo modulo fornisce 8 relè con contatti da 16A, pilotabili tramite rete LAN. Il modulo viene alimentato a 12V (anche non sfalse -
809498 ETH8020-B - 20 x 16A ethernet relay
Questo modulo fornisce 20 relè con contatti da 16A, 8 inputs analogici; pilotabili tramite rete LAN. Il modulo viene alimentfalse